Trocar(R)(Ethicon) Used Intraoperative Endoscopy in Acute Lower Gastrointestinal Bleeding.
- Author:
Jung Min BAE
1
;
Hyun Kyu LEE
;
Jong Dae BAE
;
Eun A CHOI
;
Ki Hoon JUNG
;
Byung Wook JUNG
;
Chang Young CHUNG
;
Gil Seon CHOI
Author Information
1. Department of Surgery, Dongguk University Medical College, Gyeongju, Korea. jongdals@netian.com
- Publication Type:Case Report
- Keywords:
Trocar(R) (Ethicon);
Intraoperative endoscopy;
Acute lower gastrointestinal bleeding
- MeSH:
Angiography;
Colonoscopy;
Emergencies;
Endoscopy*;
Hemorrhage*;
Humans;
Laparotomy;
Radionuclide Imaging
- From:Journal of the Korean Surgical Society
2004;66(5):424-429
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Occasionally it is difficult to preoperatively confirm the bleeding focus in acute lower gastrointestinal bleeding patients. Therefore, many diagnostic evaluations are needed - for example, colonoscopy, selective mesenteric angiography and Tc-99m RBC scintigraphy. However, if the bleeding focus remains unconfirmed preoperatively when the patient's state is unstable hemodynamically, the surgeon must inevitably perform exploratory laparotomy, followed by intraoperative endoscopy. We herein propose a new method of intraoperative endoscopy using Trocar(R) (Ethicon). Trocar(R) (Ethicon) was used in laparoscopic operation. This method has the merits of no air leakage, no contamination, fewer complicatons and ease of evaluation. We recommend that the use of Trocar(R) (Ethicon) in intraoperative endoscopy is essential in emergency operations for acute lower gastrointestinal bleeding.