Feasibility of simultaneous cardiac catheterization and 2D echocardiogram in the measurement of right rentricular pressure-volume loops
10.3969/j.issn.1004-8812.2015.11.006
- VernacularTitle:同步心导管及2D 超声构建人肺动脉高压右心室压力容积环的研究
- Author:
Xiaoke SHANG
;
Rong LU
;
Shuna XIAO
;
Changdong ZHANG
;
Qiu QIU
;
Xi YU
;
Yousan CHEN
;
Lijun WANG
;
Liang ZHONG
;
Gangcheng ZHANG
- Publication Type:Journal Article
- Keywords:
Right ventricular;
Pulmonary artery hypertension;
Pressure-volume loop;
Cardiac catheter;
2D echocardiogram
- From:
Chinese Journal of Interventional Cardiology
2015;(11):626-630
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the feasibility of the simultaneous measurement of right ventricular pressure-volume loops by cardiac catheterization and 2D electrocardiogram. Methods Patients referred for pulmonary hypertension underwent right heart catheterization in our hospital between June 1st, 2015 and June 1st, 2017 are to be enrolled in this study. The right ventricular volume was measured simultaneously by catheter and electrocardiogram. The pressure-volume loops were constructed by the parameters of the pressure and volume in the same cardiac cycle. Results The study completed in four cases and their pressure-volume loops were drawn. The obtained images were irregular and there was no relationship among them. As a result, the construction was a failure. Conclusions The construction of the right ventricular pressure-volume loops of pulmonary hypertension patients by simultaneous catheterization and 2D electrocardiogram is difficult to overcome the technology defects.