Study of the influent factors and reconstructing condition for the virtual endoscopy technique Fly-Thru (FT) in bile duct model in vitro
10.3760/cma.j.issn.1004-4477.2015.10.022
- VernacularTitle:超声仿真内镜技术Fly-Thru图像重建影响因素的体外研究
- Author:
Xiaoer ZHANG
;
Ming XU
;
Wei WANG
;
Guangliang HUANG
;
Luyao ZHOU
;
Xiaoyan XIE
- Publication Type:Journal Article
- Keywords:
Ultrasonography,three-dimensional;
Biliary tract;
Models,anatomic;
Fly-Thru technique
- From:
Chinese Journal of Ultrasonography
2015;24(10):902-906
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the factors affecting Fly-Thru (FT) and the best reconstruction conditions in a bile duct model.Methods The bile duct model was made with corn powder and rubber pipes.FT data of bile duct in vitro were acquired with a 3-dimensional probe of Toshiba Aplio 500,and the data were reconstructed offline in Fly-Thru workstation.Two US doctors assessed the FT images in three degrees.Results The images were divided into good,moderate and poor groups with corresponding score 3,2,1.Of 162 images,72 were rated as grade 1,57 as grade 2 and 33 as grade 3.According to x2 analysis,the diameter,scanning way,and Filter were brought into multinomial regression,then the scanning way was found to be correlated to FT images quality as well as filter (likelihood ratio =87.598,294.290,x2 =9.492,313.722,respectively,P <0.01).Best images of FT can be acquired by transverse scanning,reconstructing in Filter =3,gain =5(0,dynamic range (DR) =50 and threshold ranging 40-90.Conclusions Best FT images in the model could be achieved by scanning in short-axis,and reconstructing the data in Filter =3,gain =50,DR =5(0 and threshold ranging 40-90,which would be basic information for advanced clinic study.