The application of conventional ultrasonography combined with ultrasonic elastography in the differential diagnosis of thyroid nodules
10.16571/j.cnki.1008-8199.2015.10.014
- VernacularTitle:弹性成像与常规超声联合评分鉴别甲状腺良恶性结节的诊断价值
- Author:
Chunrui LIU
;
Bin YANG
- Publication Type:Journal Article
- Keywords:
Thyroid imaging reporting and data system;
Ultrasound elastography;
Thyroid nodule;
thyroid ultrasonography
- From:
Journal of Medical Postgraduates
2015;28(10):1071-1074
- CountryChina
- Language:Chinese
-
Abstract:
Objective The increased use of high-resolution ultrasound (US) for thyroid disease has markedly increased the detection rate of nonpalpable thyroid nodules .The objective of this study was to investigate the diagnostic value of conventional ultrasonography, ultrasonic elastography(UE) and combined application of both in the differential diagnosis of thyroid nodules. Methods A retrospective analysis was made on 105 patients with 160 histologically proved thyroid nodules from September 2014 and August 2015 in our hospital.The receiver operating characteristic ( ROC) curve analysis was made on Thyroid Imaging Repor-ting and Data System ( TI-RADS) score, elastography score and the score of combined application.The area under curve ( AUC) was calculated and compared to select the best cut-off value in order to work out the respective diagnostic efficacy of 3 methods and Kappa consistence check with pathologic results . Results In ROC curve analysis, AUC of combination score(0.930, 95%CI:0.890-0.969) was higher than those of TI-RADS score(0.855, 95%CI:0.794-0.915) and elasticity score(0.845, 95%CI:0.780-0.909), and the difference was statistically significant (Z=2.20, 2.03, P<0.05) .Taking TI-RADS score≥4, elastography score≥3, and combination score≥7 as the limitation to diagnose ma-lignant thyroid nodules, the specificity and PPV of combination score(94.3%, 95%CI:0.867-0.979;91.7%, 95%CI:0.809-0.969) were higher than those of TI-RADS score(78.4%, 95%CI:0.681-0.862;84.7%, 95%CI:0.692-0.886) and e-lasticity score(81.8%, 95%CI:0.719-0.889;78.7%,95%CI:0.674-0.870).Kappa value of combination score(0.718, 95%CI:0.610-0.826) was higher than that of TI-RADS score(0.586, 95%CI:0.461-0.711) and elasticity score(0.635, 95%CI:0.515-0.755). Conclusion Conventional ultrasonography and UE are mutual complementation, and the application of conventional ultrasonography combined with UE has higher value than single examination in the differential diagnosis of thyroid nodules.