Experimental study on the characters of the FITC-CSNRDARRC molecular probe and its targeted ability for orthotopic transplanted tumor of bladder cancer in vivo
10.3760/cma.j.issn.1000-6702.2015.09.018
- VernacularTitle:异硫氰酸荧光素-CSNRDARRC分子探针的荧光特性及其在体标记膀胱癌原位移植瘤的靶向性研究
- Author:
Sanhua YAN
;
Jianzhi PANG
;
Xiaofeng YANG
;
Jiehao LIU
;
Ziqiang ZHANG
;
Fan ZHANG
;
Junqian LUO
- Publication Type:Journal Article
- Keywords:
Fluorescein isothiocyanate-CSNRDARRC molecular probe;
Orthotopic transplantation tumor of bladder cancer;
Targeting
- From:
Chinese Journal of Urology
2015;36(9):699-704
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the characters and targeted ability of FITC-CSNRDARRC molecular probe in labeling orthotopic transplantation tumor of bladder cancer in vivo.Methods From July 2013 to June 2014,the stability and characters of FITC-CSNRDARRC molecular probe were detected by spectrophotometer and molecular imaging and the optimum concentration and imaging time window were determined.30 BALB-C nude mice were randomly divided into experimental group (n =20) and control group(n =10).In control group,5 of them (group A) were ligated bilateral ureter,others(group B) were not.We established orthotropic transplanted bladder tumor (BIU-87) model by operation.And 0.2 ml probes (220 μmol/L) was then injected intravenously in all mice after 2 weeks.We obtained images and analyzed average gray value of the heart,lung,liver,spleen,bilateral kidney and orthotropic transplantation bladder tumor by using optical probe molecule fluorescence imaging system after 30 min,1 h,2 h,4 h and 12 h,respectively.Results After injected the FITC-CSNRDARRC molecular probes intravenously at 220 μmol/L,the fluorescence signal of tumor tissue strengthened gradually.The optimal imaging time window was 4 hours after injection.The illumination and temperature had little effect on the fluorescence signal.With the time passing after injection,the intensity of florescence signal progressively increasing,which reached the peak at4 h.The average gray value of tumor tissue at 1 h,2 h,3 h,4 h,5 h,6 h,8 h,12 h were 74.22,76.2,80.11,89.38,83.29,85.1,81.22,83.01,respectively.The fluorescence signal of normal tissue weakened gradually with the passage of time.Only liver and gall bladder could notice the fluorescence signal 4 hours after injection in group A.However,the relatively strong fluorescence signal could be found in liver and gall bladder in group B.Conclusions The characters of fluorescence probe are affected by its concentration.Its optimal concentration of labeling tumor is 220 μmol/L.The optical imaging time window was about 4 h after intravenous injection.The FITC-CSNRDARRC molecular probe can specifically bound to orthotopic transplanted tumor of bladder cancer in vivo.