Pharmacokinetics for the solutable type injections of propofol glycoside in rats
10.3969/j.issn.1671-167X.2015.05.023
- VernacularTitle:葡萄糖基化丙泊酚溶液型注射剂在大鼠体内的药物动力学
- Author:
Zhe ZHANG
;
Ruijun JU
;
Xuetao LI
;
Dongxiao ZHANG
;
Renrong WU
;
Xuejun CHEN
;
Wanliang LU
- Publication Type:Journal Article
- Keywords:
Propofol;
Glycosylation;
Injection;
Pharmacokinetics;
Glucose
- From:
Journal of Peking University(Health Sciences)
2015;(5):846-852
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To estimate the pharmacokinetics for two solution types of propofol glycoside in-jections in rats .Methods:A high performance liquid chromatography-high resolution mass spectrometry ( HPLC-MS) was established for measuring propofol in rat plasma .Two kinds of propofol glycoside injec-tions were developed and intravenously administered to rats via tail vein , respectively , and a commercial-ly available propofol emulsion injection was intravenously administered as a control .Propofol plasma concentration-time curves were determined , and the pharmacokinetic parameters were estimated .Re-sults:HPLC-MS measurement was performed by using a quadrupole-orbit trap high-resolution mass spec-trometer on a C18 chromatographic column.The mobile phase consisted of water and methanol (20∶80, V/V) .The ion source was an atmospheric pressure chemical ion source , and the negative ion was used for detection with a scanning mode of selective ion monitoring in which m/z 177.127 4 was used for propofol and m/z 149.096 1 used for thymol as an internal standard .A linear correlation between con-centration and peak area ratio was constructed in the range of 50 μg/L-10.0 mg/L propofol.The limit of quantification was 50μg/L propofol .The average recoveries of propofol from plasma were in the range of 93.6% -101.1%, and intra-day or inter-day relative standard deviation for measurement was <14%.The pharmacokinetic results showed that the two kinds of propofol glycoside injections exhibited the same pharmacokinetic behavior .However, the clearance and area under curve values of propofol for the two propofol glycoside injections were evidently increased as compared with those for propofol emulsion injection, respectively.Furthermore, their apparent distribution volumes were increased as well .Never-theless, the propofol elimination half-life (t1/2) value of the newly developed propofol glycoside injections was the same as that of commercial propofol emulsion injection (approximately 1.5 h).Conclusion:The established HPLC-MS method can be used for measuring propofol concentration accurately in rat plasma . The clearance and distribution volumes of propofol glycoside injection are bigger than those of the propofol emulsion injection .