The finite element analysis of deformation of maxillary sinus mucosa when elevated by three lift materials
10.3969/j.issn.1001-3733.2014.06.021
- VernacularTitle:3种提升材料对闭合式上颌窦底提升术上颌窦黏膜形变影响的力学分析
- Author:
Xiaofang LIU
;
Lingling HU
;
Guangbao SONG
;
Longquan SHAO
;
Xiaobin ZHU
;
Dalie LIU
;
Jincai ZHANG
- Publication Type:Journal Article
- Keywords:
Maxillary sinus mucosa;
Deformation;
Von mise stress;
Finite element analysis;
Maxillary sinus lift
- From:
Journal of Practical Stomatology
2014;(6):831-834
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the maxillary sinus mucosa's stress distribution when elevated by three lift materials.Methods:Three Finite element models of maxillary sinus mucosa with 0.3 mm thickness elevated by implant,grafting autogenous cancellous bone and hydroxyapatite respectively were established in the specific units.ANSYS finite element analysis software was used to evaluate maxillary sinus mucosa deformation by the simulated closed sinus lift surgery.Differences of Von Mises stress values of mucosa surface were calculated when maxillary sinus mucosa lift height was increased from 1 mm to 5 mm according to the a large deformation theory. Results:The Von Mises stress values on membrane surface elevated by implant,grafting autogenous cancellous bone and hydroxyapa-tite bone substitute materials showed no difference within 5 mm elevation.Conclusion:Closed maxillary sinus floor lifting operation with implant elevating the maxillary sinus membrane directly is a simple and minimally invasive way for sinus floor elevation.