Research on the value of holter monitoring in the evaluation of silent myocardial ischemia
10.3969/J.ISSN.1672-8270.2015.03.013
- VernacularTitle:动态心电图在评价无痛性心肌缺血中的应用
- Author:
Xiaohua MA
;
Yurong MIN
;
Qigao ZHANG
- Publication Type:Journal Article
- Keywords:
Holter;
Silent myocardial ischemia;
Heart rate
- From:
China Medical Equipment
2015;(3):40-42
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the value of the Holter monitoring in silent myocardial ischemia (SMI).Methods: Sixty-eight patients with silent myocardial ischemia had the Holter monitoring.Results:Sixty-eight cases were detected 263 times of the SMI, Among them 05:00-12:00 highest incidence occurs 156 times total, 52.88% of the total number; second highest incidence of the time period of 18:00-22:00, total occurred 97 times, the total number of of 32.88%; 22:00-05:00 totaling occurred 46 times, the total number of 15.59%. There are a total of 187 predisposing factors array times, 63.34% of the total number. Heart rate greater than 100 bpm, SMI total array occurred 175 times, 59.32% of the total number; heart rate>65 bpm and