Delayed scanning method in multi-slice spiral CT for diagnosis of pulmonary embolism
- VernacularTitle:MSCTA诊断肺栓塞扫描延迟方法的探讨
- Author:
Chuanming FU
;
Wen CHEN
;
Xiaohong GONG
;
Lungang CHEN
;
Kaihua WANG
;
Jianhua ZOU
- Publication Type:Journal Article
- Keywords:
Tomography,X-ray computer;
Pulmonary embolism;
Scan delay
- From:
Chinese Journal of Interventional Imaging and Therapy
2009;6(4):321-323
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare different delayed scanning methods in multi-slice spiral CT angiography (MSCTA)in diagnosis of pulmonary embolism (PE). Methods Sixty patients with suspected PE were divided into three groups (A, B and C). MSCT with same Iodine concentration, injection rate, contrast medium but different delayed scanning methods was performed after injection of contrast medium. Patients in group A were examined with fixed time method (15 s), in group B with small dose-density curve method, while in group C with contrast medium track and triggering technoligy. The number, position and the shapes of emboli were evaluated with MIP, MPR and VR. Results The successful examination rate of group A was 55.00% (11/20), while of group B and C was both 100%. The coincidence rate of MSCTA compared with DSA in each group was 96.04% (291/303). Conclusion The best delayed scanning method in MSCTA for diagnosis of pulmonary embolism is contrast medium tracking and triggering technology.