Comparison of radiation field irradiated by different focusing modes of γ-knife
10.3760/cma.j.issn.0254-5098.2015.05.018
- VernacularTitle:γ刀不同聚焦方式形成的辐射野比较
- Author:
Feng LU
;
Gang SONG
;
Mingwei BI
;
Jiaang XU
;
Qian LIU
;
Yingmin CHEN
;
Daping DENG
- Publication Type:Journal Article
- Keywords:
γ-knife;
Radiation field;
Focusing mode;
Dose
- From:
Chinese Journal of Radiological Medicine and Protection
2015;35(5):384-388
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the single-shot fields irradiated by three focusing modes of γ-knife and explore the approaches for improving the quality of stereotactic radiosurgery.Methods GAFCHROMIC(R) EBT3 mode flushing-free film was used to measure the single-shot fields irradiated by multi-source static focusing modes,multi-source single-axis rotating focusing mode and single-source double-axis rotating focusing mode of γ-knife.Also the uniformity and penumbra of the single-shot fields were compared.Results The 2D dose distribution of the single-shot fields irradiated by three focusing modes of γ-knife was different.In the axis (x,y,z),the rang of penumbra axial length ratios of multisource static focusing modes,multi-source single-axis rotating focusing mode and single-source double-axis rotating focusing mode were 0.13-0.48,0.17-0.33 and 0.28-0.54,in the diagonal direction of the wings plane (NSD,PSD),were 0.31-0.39,0.38-0.43 and 0.54-0.72,respectively;the penumbra axial length ratio of single-source double-axis rotating focusing mode was bigger than in multi-source static focusing modes and multi-source single-axis rotating focusing mode.On the no-wings plane,the area ratios of 80% dose curve enveloped and 50% dose curve enveloped(A80%/A50%)were 0.40,0.47 and 0.19,on the wings plane,were 0.61,0.53 and 0.35,respectively.The field uniformity of multi-source static focusing modes and multi-source single-axis rotating focusing mode were superior to single-source doubleaxis rotating focusing mode.Conclusions Considering dose distribution of the single-shot fields,the multi-source static focusing modes devices and the multi-source single-axis rotating focusing mode devices should be preferred,when important tissues and organs are adjacent to the target areas.Compared with single-source double-axis rotating focusing mode,both multi-source static focusing modes and multi-source single-axis rotating focusing mode could make more target areas to be surrounded by high dose region.