Two kinds of artificial valve rings in the treatment of degenerative mitral regurgitation due to pure mitral valve ring expansion
10.3969/j.issn.2095-4344.2015.16.022
- VernacularTitle:两种人工瓣环置入修复单纯二尖瓣环扩张引起的二尖瓣关闭不全的比较
- Author:
Jinsong HAN
;
Huishan WANG
;
Zongtao YIN
;
Tingting WANG
;
Hongguang HAN
;
Hengchang SONG
;
Yan JIN
;
Yan ZHU
;
Zhaohui CHEN
- Publication Type:Journal Article
- From:
Chinese Journal of Tissue Engineering Research
2015;19(16):2578-2582
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND:Incidence of degenerative mitral regurgitation show a gradual increase tendency,but there is no report on degenerative mitral regurgitation due to pure mitral valve ring expansion in China.OBJECTIVE:To summarze the early and midterm outcomes of pure mitral valve annuloplasty in the treatment of degenerative mitral regurgitation due to pure mitral valve ring expansion. METHODS :Forty-eight patients with degenerative mitrlal regurgitation due to pure mitral valve ring expansion underwent pure mitral valve annuloplasty, including 23 cases treated with Carpentier-Edwards Physio ring and 23 with SJMTM rigid saddle ring.Affter discharge,echocardiography was used to evaluate heart function and mitral regurgitation degree during the follow-up.The outcomes were compared between the two groups. RWSULTS AND CONCLUSION:There was no early death after operation and all cases were cured and discharged.All patients were followed up for 3 months to 4years,and the cardiac function and mitral valve regurgitation were significantly improved (no mitral regurgitation in 36 cases,trivial regurgitation in 10 cases and mild mitral regurgitation in 2cases).According to NYHA grading,there were 32 cases of level 1 and 16 ceses of level Ⅱ. The echocardiography showed that postoperative left atrium diameter, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, pulmonary artery systolic pressure and the ratio of regurgitation beam area to left atrial area were significantly lower than those before operation (P < 0.01). The left ventricular ejection fraction increased greatly (P < 0.01). There was no ring rupture, ring avulsion and hemolysis. Postoperative transvalvular pressure was less than 3 mm Hg. However, there were no significant differences in the above-mentioned parameters between the Carpentier-Edwards Physio ring and SJMTM rigid saddle ring groups. The results suggest that the pure mitral valve annuloplasty is excelent in the treatment of degenerative mitral regurgitation due to pure mitral valve ring expansion, through the right surgical techniques and the right choice of artificial valve ring.