Efficiency of hemoperfusion on clearing thallium based on atomic absorption spectrometry
10.3760/cma.j.issn.2095-4352.2015.04.007
- VernacularTitle:基于原子吸收法探究血液灌流对血铊的清除作用
- Author:
Tian TIAN
;
Yongan WANG
;
Zhiyong NIE
;
Jiao WANG
;
Xiaobo PENG
;
Ye YUAN
;
Wanhua LI
;
Zewu QIU
;
Yanping XUE
;
Yiru XIONG
- Publication Type:Journal Article
- Keywords:
Thallium;
Poisoning;
Hemoperfusion;
Charcoal
- From:
Chinese Critical Care Medicine
2015;(4):259-262
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo determine thallium in whole blood by atomic absorption detection method, and to investigate the eliminating effect of hemoperfusion (HP) for thallium in blood.Methods The blood of Beagle dogs which had not exposed to thallium before were obtained for preparation of thallium nitrate (TlNO3)-containing solution in three concentrations according to the conversion formula based on animal weight and volume of blood. HP was performed in the simulated in vivo environment. The content of TlNO3 in blood of the next group was determined on the amount of TlNO3 for the last HP of the former dose group. Thallium quantity in different samples was measured with atomic absorption spectrometer blood samples before and after HP. Finally, the thallium concentration in blood was analyzed statistically.Results Thallium concentrations showed a good linear relationship in the range of 0-200μg/L (r = 0.998 4). The intra-day precision (RSD) was lower than 4.913%, the intra-day recovery rate was 96.2%-111.9%; the inter-day precision (RSD) was lower than 7.502%, the inter-day recovery rate was 89.6%-105.2%. The concentration of thallium in blood was significantly reduced after HP per time in high, middle, and low dose groups [(453.43±27.80) mg/L to (56.09±14.44) mg/L in high dose group,F = 8.820,P = 0.003;(64.51±13.60) mg/L to (3.19±0.23) mg/L in middle dose group,F = 36.312,P = 0.000; (5.40±0.98) mg/L to (0.38±0.25) mg/L in low dose group,F = 46.240,P = 0.000]. The adsorption rate of four times of HP in high, middle and low dose group were (87.63±2.48)%, (95.06±1.54)% and (92.76±4.87)%, respectively, without significant difference (F = 4.231,P = 0.070 ).Conclusions The method for measuring thallium was established, and it shows a very stable, simple, sensitive for determination of thallium. HP can effectively remove thallium from blood. Thallium concentration can be reduced by 90% after four times of HP. HP is also effective even when thallium concentration is not high.