The correlation between lesion size and contrast-enhanced ultrasound in breast cancer
10.3760/cmaj.i.ssn1.004-44772.0150.40.16
- VernacularTitle:乳腺癌病灶大小与超声造影表现的相关性
- Author:
Xiaoling LENG
;
Guofu HUANG
;
Fucheng MA
- Publication Type:Journal Article
- Keywords:
Ultrasonography;
Microbubbles;
Breast neoplasms;
Tumor size
- From:
Chinese Journal of Ultrasonography
2015;(4):324-327
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate whether there are differences of the characteristics of the contrast‐enhanced ultrasound among breast cancer vary in size .Methods The contrast‐enhanced ultrasound perfusion mode were retrospectively analyzed in 113 cases of breast cancer patients with 119 lesions .They were divided into two groups according to the maximum diameter of the lesion based on ultrasound measured ,one group (≤2 0. cm ) 47 cases ,the other group (> 2 0. cm ) 72 cases .The characteristics and mode of contrast‐enhanced ultrasound of the lesion were analyzed ,including whether is greater than the two‐dimensional ultrasound in enhanced range ,enhanced strength ,the distribution of the contrast agent ,contrast agent perfusion sequence in lesions ,contrast mode ,and the existence of perforator vessels and perfusion defects .Results Enhanced strength ,the existence of perforator vessels and perfusion defects associated with the size of the lesions .The breast cancer lesions more than 20 cm were apt to higher enhance strength ,the presence of perfusion defects ,perforator vessels ( P < 0 0.5) .However ,there were something that had nothing to do with the size of the lesions including whether or not contrast‐enhanced ultrasound range was greater than the two‐dimensional ultrasound range ,contrast agent distribution characteristics ,contrast agent perfusion sequence in lesions ,and differences in contrast patterns ( P >0 0.5) .Regardless of breast lesions size ,the enhanced range tended to larger than two‐dimensional ultrasound range ,and contrast‐enhanced ultrasound present inhomogeneous ,centrality and integrity filling and perfusion mode of quickly rising and falling .Conclusions Within breast tumor angiogenesis is gradual .With the increase of tumor volume ,more significant vascular heterogeneity ,breast cancer lesion are more prone to uneven high perfusion ,accompanied by perfusion defects and perforating vessels ,but the main sign of differentiating benign and malignant showed consistency between different sized lumps in breast cancer ,which included whether or not contrast mode and enhanced range greater than two‐dimensional ultrasonic range .