Objective To establish a high performance liquid chromatography (HPLC) method for the determination of geniposide in Diaojinyao powder. Methods The HPLC system consisted of the Fortis-C18 (4.6 mm × 250 mm, 5μm) column, the mobile phase consisted of HCN∶H2O (12∶88) , the flow rate was 1.0 ml/min, the column temperature was 30℃, The UV detector was set at 238 nm. Results The linear response range was 0.049~0.980mg/ml ( r=0.999 9). The average recovery of geniposide was 99.1%, and RSD was 1.66%. Conclusion The method is simple, rapid, accurate and repeatable. It can be applied in determination of Geniposide in Diaojinyao Powder.