Clinical observation on the accuracy of nostril width method in intubation model choose in children with cerebral palsy FSPR surgery
10.3969/j.issn.1671-8348.2015.05.024
- VernacularTitle:鼻孔宽度法选择小儿气管插管加强型号应用于小儿脑瘫 FSPR的效果观察
- Author:
Jiansheng HUANG
;
Rong ZHANG
;
Jianbo LIU
;
Xinxue WANG
;
Zeyu ZHAO
;
Qing CHENG
- Publication Type:Journal Article
- Keywords:
nostril width method;
pediatric intubation model of pediatric;
surgery FSPR
- From:
Chongqing Medicine
2015;(5):647-648
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the accuracy of nostril width method in intubation model choose in children with cerebral pal‐sy FSPR surgery .Methods Three hundred and fifty six cases of cerebral palsy FSPR surgery were selected ,the endotracheal intu‐bation were selected by nose width method and modified weight method ,and then we made a comparison between the two methods . Kappa consistency test and rank correlation analysis were both used to analyze the consistency .Results With Kappa=0 .81 ,rank correlation coefficient 0 .905 ,we could know that there was high degree of consistency between the two methods (P<0 .01) ,of which 298 cases (83 .7% ) children selected the same model intubation strengthen model in different method ,58 cases (16 .3% ) pe‐diatric intubation choice of two methods differ by one model .Conclusion Nostril width method was simple and reliable to select in‐tubation in pediatric surgery to strengthen FSPR model .