A control study of CT colon scans in normal adults and patients with intractable constipation after air enema for measuring colon length
10.3969/j.issn.1002-1671.2014.10.036
- VernacularTitle:CT结肠造影对正常成人与顽固性便秘患者结肠长度的对照研究
- Author:
Bin FANG
;
Junqiang LEI
;
Yanan ZHAI
;
Qihong GUO
- Publication Type:Journal Article
- Keywords:
redundant colon;
computed tomography;
post-processing techniques
- From:
Journal of Practical Radiology
2014;(10):1739-1741
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the difference of colon length between patients with intractable constipation and normal peo-ple.Methods 40 patients with intractable constipation and 35 cases of normal control group received air enema CT scan,post-pro-cessing techniques-curved planar reformation and volume rendering were used to measure the length of colon.Results Colon length of normal people and constipation patients were (1 230±33)mm and (1 605±47)mm,respectively.There was significant difference between normal people and constipation patients (t=163,P=0.015).Conclusion CT air enema technique can be used to measure the length of colon obj ectively for diagnosing and treating redundant colon.