Extreme lateral lumbar disc herniation after pedicle screw fixation and interbody fusion cage:lumbar stability at long-tem follow-up
10.3969/j.issn.2095-4344.2014.40.012
- VernacularTitle:钉棒置入与椎间融合修复极外侧型腰椎间盘突出症:远期腰椎稳定性随访
- Author:
Ruiming SHI
;
Guosheng LI
;
Yifeng ZHANG
;
Zhenyuan HUANG
;
Li SUN
;
Cun WANG
- Publication Type:Journal Article
- Keywords:
lumbar veretebrae;
intervertebral disk displacement;
internal fixators;
spinal fusion;
fol ow-up studies
- From:
Chinese Journal of Tissue Engineering Research
2014;(40):6464-6470
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND:Extreme lateral lumbar disc herniation is a rare type of lumbar disc herniation, there are a variety of treatment methods, but the therapeutic efficacy and recurrence rate are controversial.
OBJECTIVE:To investigate the availability of lumbar pedicle screw fixation combined with interbody fusion cage for treating extreme lateral lumbar disc herniation.
METHODWe retrospectively analyzed 19 patients with extreme lateral lumbar disc herniation after treatment with lumbar pedicle screw fixation combining with interbody fusion cage from March 2006 to January 2009. The outcomes were evaluated depending on VAS scoring standard and Macnab scoring standard, lumbar stability were observed postoperatively. We analyzed the spinal stability in recurrent lumbar disc herniation patients after lumbar pedicle screw fixation combined with interbody fusion cage depending on literature search.
RESULTS AND CONCLUSION:Al the 19 patients were fol owed up for 13 months to 3 years, the leg and lumbar pain of al the patients were relieved to varying degrees. Preoperative VAS score was 7.3±1.28 points and postoperative VAS score was 2.1±0.8 points, showing significant difference between two groups (P<0.05). The excellent and good rate was up to 95%with 15 excellent results, 3 good results and 1 acceptable result depending on Macnab evaluation standard. There was no pedicle screw loosening, broken, non-fusion phenomenon. Al the lumbar interbody fusions were good. No one occurred secondary lumbar spinal stenosis. Experimental findings indicate that, lumbar pedicle screw fixation combined with interbody fusion cage for extremely lateral lumbar disc herniation, is characterized as fast symptom relief, strong fixation and good lumbar stability.