Content Determination of Six Types of Heavy Metals in Pian-Zai-Huang Gan-Bao Tablets by ICP-MS
10.11842/wst.2014.08.018
- VernacularTitle:ICP-MS测定片仔癀肝宝中6种重金属的含量
- Author:
Juan YU
;
Shouying DU
;
Jue CHEN
- Publication Type:Journal Article
- Keywords:
ICP-MS;
microwave digestion;
Pian-Zai-Huang Gan-Bao tablets;
Cr;
Pb;
Cd;
As;
Hg;
Cu
- From:
World Science and Technology-Modernization of Traditional Chinese Medicine
2014;(8):1789-1795
- CountryChina
- Language:Chinese
-
Abstract:
This study was aimed to develop an ICP-MS method to determine contents of six types of heavy metals, which include Cr, Pb, Cd, As, Hg and Cu, in Pian-Zai-Huang Gan-Bao (PZHGB) tablets. The samples were pro-cessed by microwave digestion. And then, they were determined by ICP-MS. The results showed that the working curves of Cr, Cu, As, Cd, Hg and Pb had good linear relationships with the correlation coefficient which was more than 0.9993. The average recovery rate of Cr was 101.2%. The relative standard deviation (RSD) was 7.6%. The av-erage recovery rate of Cu was 96.4%, with the RSD of 3.5%. The average recovery rate of As was 101.3%, with the RSD of 1.8%. The average recovery rate of Cd was 100.2%, with the RSD of 0.3%. The average recovery rate of Hg was 100.5%, with the RSD of 4.2%. The average recovery rate of Pb was 104.2%, with the RSD of 5.6%. It was concluded that the method was stable and reliable, with high sensitivity and repeatability. This method can be used in the content determination of six types of heavy metals, which include Cr, Pb, Cd, As, Hg and Cu in PZHGB tablets.