Design and application research of PE right ventricular catheter for mice
10.3969/j.issn.1671-8348.2014.19.001
- VernacularTitle:小鼠 PE右心室导管的制作及应用研究
- Author:
Gang XU
;
Wenxiang GAO
;
Dewei CHEN
;
Xiaoxu LI
;
Fuyu LIU
;
Jian HUANG
;
Yuqi GAO
- Publication Type:Journal Article
- Keywords:
mice;
right ventricular catheter;
right ventricular systolic pressure;
Hermann-Willson index
- From:
Chongqing Medicine
2014;(19):2401-2403
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish a simple ,low cost and stable method to detect right ventricular pressure in mice .Methods A PE-50 duct length 15 cm(outside diameter :0 .9 mm ,inner diameter :0 .5 mm) was bent on one terminal and the other terminal was inserted into a 7# syringe needle to connect to a pressure transducer .This duct was intubated into right ventricle via right external jugular vein to detect right ventricular pressure in 80 SPF grade male C57BL/6 mice .Successful cases and operation time were re-corded .Besides ,40 SPF grade male C57BL/6 mice were randomized into the control group (n=20) and chronic hyperbaric hypoxia group(n= 20) .Mice in chronic hyperbaric group were raised in a hyperbaric chamber of simulated 5 000 m high altitude for 4 weeks .The control group was raised outside the chamber simultaneously .Right ventricular systolic pressure was detected with the PE duct .Left and right ventricles were detached and weighed ,and Hermann-Willson index was calculated .Results With this PE duct ,right ventricular intubation success rate was 90% (72/80) ,the operation cost approximately 3 to 5 min each mouse from the separation of blood vessels to detect the time needed for the right ventricle waveform .right ventricular systolic pressure[(39 .52 ± 4 .34 )mm Hg] and Hermann-Willson index(0 .356 ± 0 .039)of chronic hyperbaric hypoxia group were significantly higher than that of control group [(21 .24 ± 2 .7)mm Hg and (0 .256 ± 0 .020)] ,which has significant positive correlation (P<0 .01) .Conclusion It is simple ,fast ,stable ,costing low and of high success ratio to detect right ventricular pressure with this method .