Efficacy of Prolene 3D patching in tension-free hernioplasty for femoral hernia via femoral approach
10.3760/cma.j.issn.1671-7368.2014.06.019
- VernacularTitle:普里灵三维疝装置经股路修补股疝的疗效观察
- Author:
Jianpeng HUANG
;
Weixing WANG
- Publication Type:Journal Article
- Keywords:
Hernia,ventral;
Reconstructive surgical procedures
- From:
Chinese Journal of General Practitioners
2014;(6):488-489
- CountryChina
- Language:Chinese
-
Abstract:
A total of 114 cases of femoral hernia undergoing 3D Prolene patching via femoral approach were examined for duration of surgery , length of stay , recurrence , postoperative pain and complications.Among them, 53 cases received both pre-and post-operative Doppler ultrasonic examinations.The vein thrombus ,diameter and flow rate of femoral vein were observed to compare with the pre-operative data to learn whether it had difference or not.The operative duration was 13.3 minutes.There was no event of recurrence ,compression,stricture or thrombosis of femoral vein.