Preliminary clinical observation of new allograft posterior lumbar fusion cage of anatomical shape
10.3969/j.issn.1006-5725.2014.07.032
- VernacularTitle:新型后路同种异体骨解剖形腰椎融合器的疗效
- Author:
Yang LI
;
Fei LUO
;
Peng LIU
;
Yong LIANG
;
Jianzhong XU
- Publication Type:Journal Article
- Keywords:
Allograft;
Cage;
Intervertebral fusion;
Lumbar fusion
- From:
The Journal of Practical Medicine
2014;(7):1112-1115
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore preliminary clinical results of a new anatomical shape allogeneic bone posterior lumbar fusion cage. Methods Follow-up patients used the allogeneic bone posterior lumbar fusion cage and use imaging methods and clinical score (VAS, ODI) to evaluate the patients′ clinical efficacy. Results 14 patients were followed up for 6 months or more , with an average follow-up time of 9.7 months , mean preoperative VAS 6.8 ± 1.1, ODI 32.7 ± 4.5. The mean preoperative disc height was (9.7 ± 2.0) mm and the average intervertebral height of 3 days post operation was (13.2 ± 1.7) mm. All patients got bony fusion in 6 months post operation, pain and function scores improved significantly compared with the pre-operation: VAS 2.4 ± 0.8 (P =0.000), ODI 9.8 ± 2.5 (P = 0.000), the average intervertebral height was (13.1 ± 1.7) mm (P = 0.000). The average was VAS 2.1 ± 0.1 (P = 0.000), average ODI was 8.9 ± 0.9 (P = 0.000) at last follow up. Average of intervertebral height was (13.0 ± 1.8) mm, no significant difference compared to three days after surgery (P=0.831). No serious complications and deep surgical site infection was observed. All implants were found no fragmentation, shift, cutting boards, and obviously sinking. Conclusion The anatomical shape allogeneic bone posterior lumbar fusion device is suitable for posterior lumbar interbody fusion , advantages of high fusion rate , satisfactory clinical results in the initial clinical trials , but its long-term efficacy requires further observation.