Intra-operative monitoring of neuro-electrophysiology in spinal tuberculosis surgery
10.3760/cma.j.issn.0254-1424.2014.04.012
- VernacularTitle:神经电生理监测技术在脊柱结核手术中的联合应用
- Author:
Yi CHEN
;
Zhixiong LIN
;
Wen LI
;
Qi LIU
;
Jingming WU
;
Bo BAI
;
Weijie LU
- Publication Type:Journal Article
- Keywords:
Somatosensory evoked potentials;
Transcranial electrical stimulation;
Motor evoked potentials;
Spontaneous electromyography;
Intra-operative monitoring;
Spinal tuberculosis
- From:
Chinese Journal of Physical Medicine and Rehabilitation
2014;36(4):287-290
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the efficacy of combined monitoring of motor evoked potentials with transcranial electrical stimulation (TES-MEP),somatosensory evoked potentials (SEP) and spontaneous electromyo-graphy (s-EMG) in tuberculosis surgery involving the thoracic,lumbar and sacral vertebrae.Methods Twenty-seven patients with tuberculosis of the thoracic vertebrae (T2-L2) received intra-operative SEP and TES-MEP monito-ring.Combined SEP,TES-MEP and spontaneous EMG monitoring were employed in 11 patients with tuberculosis of the lumbar or/and sacral vertebrae (L3-S1).SEP and TES-MEP were used to precisely observe the status of the sen-sory and motor pathways; s-EMG responses were used to more accurately localize nerve root irritation.ResuIts (1) SEP monitoring was successful in all of the operations.TES-MEPs were successfully monitored in 35 of them (92.1%).Combined motor and sensory monitoring was successfully achieved in 35 cases (92.1%).Abnormal SEPs were observed in 3 cases (7.9%),while abnormal MEPs were observed in 11 cases (28.9%).Abnormality in both the SEP and TES-MEP occurred in 2 cases (5.3%).There were 9 cases (23.7%) where the SEPs were nor-mal and the TES-MEPs were abnormal.In only 1 case (2.6%) was the SEP normal and the MEP abnormal.The false negative rate was 0% with combined SEP and TES-MEP monitoring,while the false positive rate was 5.3%.There were 2 cases complicated by post-operative neurological deficits.(2) Spontaneous EMG monitoring can accu-rately determine the functioning of lumbar nerve roots during lumbar or lumbosacral tuberculosis surgery.Among 5 cases where EMG responses were observed,4 cases occurred during the spinal canal and nerve root decompression,1 case occurred in the orthopedic reset phase.Conclusions (1) During tuberculosis surgery involving thoracic,lumbar or sacral vertebrae,combined monitoring of SEPs and TES-MEPs can reflect the physiological and pathological condition of the spinal cord after ruling out interfering factors.This can improve monitoring and help assure the safety of lumbar surgery.(2) Intra-operative s-EMG monitoring can accurately reveal nerve root function in real time,help-ing to avert nerve root injury in lumbar and lumbosacral tuberculosis surgery.