Absorbable collagen suture and non-absorbable silk suture in oral implantation
10.3969/j.issn.2095-4344.2014.12.012
- VernacularTitle:可吸收胶原蛋白线与丝线编织非吸收线在口腔种植中的应用
- Author:
Haiyang XU
;
Hao XU
;
Li ZHANG
;
Xiaoxin QU
;
Baodong ZHAO
- Publication Type:Journal Article
- Keywords:
absorbable implants;
sutures;
col agen;
biodegradation,environmental;
surgical staplers
- From:
Chinese Journal of Tissue Engineering Research
2014;(12):1877-1882
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND:Col agen suture is made of col agen from animals, and has been widely used because it is absorbable, non-rejection and easy to produce, and convenient in use.
OBJECTIVE:To evaluate the effects of col agen suture and silk suture in wound healing after oral implant surgery.
METHODS:100 patients undergoing oral implantation were randomly assigned into col agen suture group and silk suture group. A 2-0 circular needle with absorbable col agen sutures and a 4-0 circular needle with non-absorbable silk sutures were employed for tension-free suture in the two groups. After 3, 5, 7 days of oral implantation, suture threads and wound healing were observed. The suture was removed at 14 days, and patients were reviewed at 14 days.
RESULTS AND CONCLUSION:The wound healing was better in the col agen suture group than the silk suture group at grade I (P<0.05). At 7 days postoperatively, the suture thread was mostly absorbed in the col agen group but not in the silk suture group. In addition, material alba was invisible in the col agen suture group but clear in the silk suture group. These results indicate that the col agen suture is more proper for tension-free suture than the silk suture, which is better matched to the healing time and keeps a better oral environment.