A three-dimensional finite element analysis of stress distribution in peri-implant bone with All-on-4 im-plant with various parameters
	    		
		   		
		   			 
		   		
	    	
    	 
    	10.3969/j.issn.1001-3733.2014.02.010
   		
        
        	
        		- VernacularTitle:All-on-4种植体参数对周围骨应力影响的三维有限元分析
- Author:
	        		
		        		
		        		
			        		Yuting WANG
			        		
			        		;
		        		
		        		
		        		
			        		Shaofeng ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Yan DONG
			        		
			        		;
		        		
		        		
		        		
			        		Weiguo WANG
			        		
			        		;
		        		
		        		
		        		
			        		Jipeng LIU
			        		
			        		;
		        		
		        		
		        		
			        		Jiawen GUO
			        		
			        		
		        		
		        		
		        		
 
			        		
			        		
		        		 
- Publication Type:Journal Article
- Keywords:
        			
	        			
	        				
	        				
			        		
				        		All-on-4;
			        		
			        		
			        		
				        		Stress;
			        		
			        		
			        		
				        		Finite element analysis
			        		
			        		
	        			
        			
        		
- From:
	            		
	            			Journal of Practical Stomatology
	            		
	            		 2014;(2):193-197
	            	
            	
- CountryChina
- Language:Chinese
- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To investigate the stress distribution in peri-implant bone with All-on-4 implant with various parameters by three-dimensional finite element method.Methods:An edentulous mandibular specimen was scanned by CT Mimcs.Geomagic,Uni-graphics,HyperMesh modeling software were used to establish All-on-4 implant finite element models with different inclination angles and corresponding cantilever lengths.1 50 N vertical static load was applied at the right end of the cantilever,peri-implant bone stress was analysed using Abaqus software.Results:When the distal implant inclined 0°with cantilever length of 1 9.5 mm,the peak stress in peri-implant cortical bone at the mesial and distal side was 25.526 MPa and 83.026 MPa respectively.When the distal implant in-clined 1 5°,30°and 45°with the cantilever length of 1 7.2 mm,1 3.3 mm and 9.8 mm,the stress in perio-implant cortical bone at distal side of the implant reduced by 1 2.4%,35.6% and 53.1 %,that at mesial side of the implant reduced by 1 3.6%,36.3% and 40.2%,respectively.Conclusion:From the perspective of the stress analysis,the design of All-on-4 distal implant with large incli-nation angle and short cantilever is superior to that with small inclination angle and long cantilever.