Morphologic diagnosis analysis of CTA technical on myocardial bridge-wall coronary artery
10.3969/J.ISSN.1672-8270.2014.02.032
- VernacularTitle:CTA技术对心肌桥-壁冠状动脉血管的形态学诊断分析
- Author:
Wangming GUO
;
Guixiang REN
;
Xueqing WANG
- Publication Type:Journal Article
- Keywords:
Myocardial bridge-wall coronary artery;
Spiral CT angiography;
Coronary angiography
- From:
China Medical Equipment
2014;(2):87-89
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To discuss the morphologic diagnosis value of CTA technical on myocardial bridge-wall coronary artery. Methods: Three hundred and seventy seven patients suspected MB-MCA and with CTA and CAG inspection voluntary in cardiology clinic or hospital were analyzed, and the occurrence of type MB-MCA and MCA MB length and degree of stenosis were recorded, the results were analyzed using SPSS17.0 statistical software. Results:103 cases of 377 were diagnosed as final MB-MCA, and there were 110 MB-MCA in total. CTA and CAG checked by means of two kinds of shallow and deep in the model type MB-MCA diagnostic analysis were compared through Kappa analysis, the Kappa value were 0.803 and 1.000. Two methods had a good consistency in the diagnosis of MB-MCA;There were statistically significant in CTA and CAG two kinds of examination methods in the diagnosis of superficial in type (t=-5.149)and deep in the type MB (t=-2.457, P=0.024)(P<0.05). Conclusion:The multi-slice spiral CT angiography CTA technology has good consistency with CAG in MB-MCA diagnosis, can achieve complementary advantages, can combine their respective advantages MB-MCA to improve the diagnostic accuracy for clinical richer diagnostic information.