The performance of △POP in the assessment of fluid responsiveness in septic shock patients in emergency department
10.3760/cma.j.issn.1671-0282.2014.01.005
- VernacularTitle:脉搏血氧波形振幅变异率在急诊感染性休克患者容量复苏中的作用
- Author:
Yecheng LIU
;
Jun XU
;
Huadong ZHU
;
Zhong WANG
;
Xuezhong YU
- Publication Type:Journal Article
- Keywords:
Fluid responsiveness;
Septic shock;
Emergency department
- From:
Chinese Journal of Emergency Medicine
2014;23(1):15-18
- CountryChina
- Language:Chinese
-
Abstract:
Objective Respiratory variations in the pulse oximetry plethysmographic waveform amplitude (△POP) have been popularly studied as a dynamic indicators for fluid responsiveness assessment.The authors hypothesized that △POP can indicate fluid responsiveness in septic shock patient in emergency department.Methods A prospective study of 28 patients with septic shock was carried out in Emergency Room and Emergency Intensive Care Unit from 1 October,2010 to 30 September,2011.Hemodynamic data including cardiac index,stroke volume Variation (SVV) and △POP were recorded before and after volume expansion treatment.Fluid responsiveness was defined as an increase in cardiac index of 15% or greater.Results Changes in △POP after volume expansion were greater in responders than that in non-responders (P < 0.01).There was a significant relation between △POP and SVV before volume expansion (r =0.900,P < 0.0001).Conclusions △POPcan indicate fluid responsiveness non-invasively in septic shock patient in emergency department.This marker has potential clinical application with high sensitivity and reliability.