Study on the technical application for the vitreous humor section and removal of the intraocular foreign body by par plan
- Author:
Hon Nhu Do
- Publication Type:Journal Article
- Keywords:
intraocular foreign body
- MeSH:
Injuries;
Foreign Bodies
- From:Journal of Vietnamese Medicine
1999;232(1):24-30
- CountryViet Nam
- Language:Vietnamese
-
Abstract:
51 eyes of 50 patients with the ophthalmological traumatic in the traumatic department of the institute of ophthalmology during 1996 - 1998 were studied. They are mainly men with ages of under 40, injuries during working. The foreign body passed over the cornea and broken the lens (62.74%). The size of the foreign body less than 3mm accounts for 70.8%. The technique of vitreous humor section though par plan was implemented under surgical microseopy for removal of the foreign body (the sucessful rate: 86.27%). The vision is generally low. The common complications were post-operative intraocular bleeding and the retinal detachment.