Role of thoracic electrical bioimpedance monitoring in the evaluation of cardiac function in peritoneal dialysis patients
10.3760/cma.j.issn.1001-7097.2013.09.003
- VernacularTitle:胸阻抗监测对腹膜透析患者心功能评价的作用
- Author:
Xiao JIANG
;
Yuxin SHEN
;
Zhiwei HU
;
Min ZHAO
;
Xiangming QI
;
Yonggui WU
- Publication Type:Journal Article
- Keywords:
Peritoneal dialysis;
Echocardiography,Doppler,color;
Cardiac function;
Thoracic electrical bioimpedance
- From:
Chinese Journal of Nephrology
2013;29(9):655-659
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the effectiveness of thoracic electrical bioimpedance(TEB)in monitoring the cardiac function of peritoneal dialysis patients.Methods One hundred and one patients with continuous ambulatory peritoneal dialysis (CAPD) and 30 healthy persons (control group)were included in the study.Thoracic electrical bioimpedance (TEB) noninvasive hcmodynamic monitoring and echocardiography were taken to analyze the correlation between indexes.Results Echocardiography showed that left atrial diameter (LAD),left ventricular end diastolic diameter (LVDd),left ventricular end systolic diameter (LVDs),interventricular septal thickness (IVST),interventricular septal thickness (PAP),left ventricle weight index (LVMI) of CAPD group were higher than that of the control group (all P < 0.05),early and late wave of mitral valve flow (E/A) of CAPD group was lower than that of control group (P < 0.05).TEB monitoring showed that cardiac output (CO),stroke volume (SV),acceleration index (ACI),ejection fraction (EF),velocity index (Ⅵ) of CAPD group were significantly lower than that of control group (all P < 0.01),systolic time ratio (STR),SVR,TFC of CAPD group were significantly higher than that of control group (P < 0.01).Correlation analysis show that left ventricular ejection fraction (LVEF) was negatively correlated with BNP (r =-0.467,P < 0.01),LVMI was positively correlated with BNP (r=0.416,P < 0.01),PEP,STR and TFC were positively correlated with BNP (r =0.404,P < 0.01; r =0.572,P < 0.01; r=0.471,P < 0.01),EF was negatively correlated with BNP (r =-0.664,P < 0.01).Correlation analysis between echocardiogaphy and TEB monitoring index showed there was significant correlation between EF and LVEF (r =0.451,P < 0.01),SVR and TFC were positively correlated with LVMI (r =0.232,P < 0.05; r =0.284,P < 0.05),SV was positively correlated with E/A (r =0.285,P < 0.05),pre-ejection period (PEP) and STR were negatively correlated with LVEF (r =-0.389,P < 0.01; r =-0.446,P < 0.01),TFC was positively correlated with LAD (r=0.279,P < 0.05).Conclusion TEB monitoring can accurately evaluate the cardiac function with the advantage of dynamic monitoring and simple operation.It can partly replace the echocardiography test.