Evaluation of speckle-tracking imaging in differential diagnosis of dilated cardiomyopathy and ischemic cardiomyopathy
10.3760/cma.j.issn.1004-4477.2013.10.001
- VernacularTitle:斑点追踪成像技术鉴别诊断扩张型心肌病与缺血性心肌病的价值探讨
- Author:
Dongmo WANG
;
Jiawei TIAN
;
Min REN
;
Guoqing DU
- Publication Type:Journal Article
- Keywords:
Echocardiography;
Cardiomyopathy,dilated;
Coronary disease;
Speckle tracking imaging
- From:
Chinese Journal of Ultrasonography
2013;22(10):829-833
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the differential diagnostic value of speckle-tracking imaging (STI) between dilated cardiomyopathy(DCM) and ischemic cardiomyopathy(ICM).Methods 40 DCM patients,32 ICM patients and 30 normal controls were enrolled for this study.Different views of high frame images of left ventricle were recorded.The time to peak radial strain,circumferential strain and longitudinal strain of 18 myocardial segments were measured by STI,and the maximum differential (Ts-dif) and the standard deviation(Ts-SD) of time to the peak strain were calculated.The left ventricular parameters measured by STI were compared between DCM and ICM,and the diagnostic sensitivity and specificity were investigated by the areas under the receiver operating characteristic (ROC) curves.Results Parameters of different segments of ICM were obviously higher than those of DCM (P < 0.05),and there were significant differences between ICM and DCM.The areas under the ROC curves of Ts-dif and Ts-SD to radial strain were 0.920 and 0.946 respectively.At the cut off of 170 ms and 53 ms for diagnosing DCM and ICM,the sensitivity,specificity and accuracy were 87.5%,87.5%,87.5% and 90.6%,90%,90.2% respectively.Conclusions These strain parameters by STI,especially Ts-SD to peak strain can offer a new quantitative diagnostic method in distinguishing DCM from ICM.