The feasibility study of low tube voltage combined with low contrast dose in multi-slice CT skull arteriography
10.3760/cma.j.issn.1005-1201.2013.11.007
- VernacularTitle:低管电压结合低剂量对比剂在多层螺旋CT头颅动脉血管成像中应用的可行性研究
- Author:
Wei XIA
;
Xiaorui YIN
;
Jingtao WU
;
Yuan ZHOU
;
Zhijun WANG
- Publication Type:Journal Article
- Keywords:
Tomography,X-ray computed;
Radiation dosage;
Comparative study
- From:
Chinese Journal of Radiology
2013;47(11):984-987
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the feasibility of a low-dose contrast medium protocol for 64-slice CT angiography (CTA) of head using a low-tube-voltage setting.Methods ① Phantom study:64-slice spiral CT respectively sets 80,100,120,140 kV and 100,200,300,400,500 and 600 mA as scanning parameter lines.Analysis of the best Signal-to-noise ratios (SNR) and contrast to noise ratios (CNR).②Clinical study:to prospectively continuous select sixty-six patients with suspected intracranial aneurysm and arteriovenous malformation and so on from April to October of 2012 to perform hand CTA inspection.The random number table method for A,B two groups,33 patients in each group.Group A (conventional group)scanning parameters:120 kV,400 mA and amount of contrast agent:1 ml/kg; Group B(test group) scanning parameters:80 kV,600 mA,amount of contrast agent 0.5 ml/kg.Using independent samples t test for each group radiation dose,SNR,CNR were statistically analyzed.By two experienced radiologists to 5 points on two groups of image quality subjective evaluation.Mann-Whitney U test was used for statistical analysis of subjective evaluation.Results Group A and B group CTDIvol respectively is 59.1,27.5 mGy.Group B than in group A,CTDIvol decreased by 53.5%.A,B groups of the SNR,CNR were 71.5 ± 10.7,92.0 ± 7.4; 58.5 ± 10.5,79.6 ± 7.7,Group B than in group A SNR,CNR were enhanced by 22.3%,26.4%,differences were statistics significance (t =584.0,388.6,P < 0.01).The subjective image evaluation of group B was bigher than group A (Z =31.2,23.4,P < 0.05),differences were statistics significance.Two physicians on CTA images to assess the consistency of uniform height(Kappa =0.904,P <0.05).Conclusion In the head CTA examination,use of low tube voltage combined with low contrast dose not only can improve the image quality but also radiation dose were significantly lower.