Clinical study on echocardiography combined with end-tidal CO2 monitoring in preventing the venous air embolism during operative hysteroscopy
10.3760/cma.j.issn.0529-567x.2013.11.007
- VernacularTitle:超声心动图联合呼气末CO2分压监测预防宫腔镜术中空气栓塞的临床研究
- Author:
Yunqiao XU
;
Juxin ZHANG
- Publication Type:Journal Article
- Keywords:
Embolism,air;
Echocardiography;
Capnography;
Hysteroscopy
- From:
Chinese Journal of Obstetrics and Gynecology
2013;48(11):828-832
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the value of transthoracic echocardiography(TTE) combined with partial pressure of end-tidal CO2 (PETCO2) monitoring in preventing venous air embolism (VAE) during hysteroscopy operation.Methods From August 2010 to August 2012,300 cases undergoing hysteroscopic surgery under general anaesthesia were enrolled in this study.With the echocardiography combined with PETCO2 monitoring during hysteroscopic surgery,the time of VAE appearing in the right atrium,the extent of air embolism(grade 0-4),the changes of PET CO2,peripheral oxygen saturation (SpO2),blood pressure (Bp),the amount of fluid intravasation and the blood loss were recorded in detail.Take the 24 cases that the grades of VAE in grade 3 or above and a decrease in PETCO2 ≥5 mm Hg (1 mm Hg =0.133 kPa) as intervention group.Stop operation immediately,the left side and raise your right shoulder,oxygen inhalation and dexamethasone 10 mg intravenous drip were given to the intervention group; the control group (5 cases in grade 3 or above and a decrease in PETCO2 < 5 mm Hg) only stop operation immediately,observation patient's condition closely.Results (1) The occurrence of VAE:air embolism occurred in 34 patients among all 300 patients,all of 34 patients had evidence of gas embolism in the inferior vena cava,right atrium(RA) and right ventricle chamber,and 29 patients had evidence of continuous groups of gas emboli.There were 32 cases with the decrease in PETCO2 > 2 mm Hg,14 cases with SpO2 less than 95%,and 4 cases with a drop in Bp ≥ 20%.(2) The change of the decrease of PET CO2 and the grades of VAE:the decrease of PETCO2 and the grades of VAE were positively correlated (r =0.601,P < 0.01),continuous groups of gas emboli signal in RA,when the drop of PETCO2 ≥5 mm Hg,8 of the 34 cases whose drop of PETCO2 ≥ 10 mm Hg,7 cases in grades 4.The decrease of PET CO2 [(7.5 ± 2.4) mm Hg versus (11.1 ±4.1)mm Hg],the amount of fluid intravasation[(688 ± 150) ml versus (925 ±268) ml] and the blood loss [(71 ± 36) ml versus (127 ± 56) ml] all had statistical difference in grade 3 and 4 (P < 0.05).The sensitivity of PETCO2 was better than SpO2 and Bp in detecting of VAE.(3)The cases of PETCO2 continue to decline and recovery time between the two groups:2 cases' PETCO2 continued to decline in the intervention group,but 4 cases in the control group.The recovery time of the two groups was(4.8 ± 1.6) and (8.3 ±1.9) min,respectively,which reached statistical difference between (P < 0.05).Conclusions TTE combined with PET CO2 monitoring can effectivelv predict the occurrence of air embolism in hysteroscopic surgery; Continuous groups of gas emboli signal in RA accompanied by a decrease in PETCO2 ≥5 mm Hgindicates that the occuTence of air embolism ; the more the amount of intravasation of distension fluid and the blood loss,the more the air into the body.Timely intewention can effectively prevent the development of air embolism when the VAE in grade 3 or above accompanied by a decrease in PETC02 ≥5 mm Hg.