Application of FMEA in reducing unplanned extubation of PICC
10.3760/cma.j.issn.1672-7088.2013.18.030
- VernacularTitle:失效模式效应分析在减少PICC非计划拔管中的应用
- Author:
Haiyun JIANG
;
Yao TANG
- Publication Type:Journal Article
- Keywords:
Failure mode;
Peripherally inserted central catheter;
Unplanned extubation
- From:
Chinese Journal of Practical Nursing
2013;(18):63-65
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the application effect of FMEA in reduction of unplanned extubation of PICC.Methods FMEA was applied to find out the failure mode of unplanned extubation of PICC,and then assessed it from three dimensions,which were the likelihood of occurrence,the possibility of being discovered,and the seriousness of the failure,and then calculated the RPN values,risk priority,and plan optimization process,at the last made a proactive behavior intervention.81 patients were selected as the control group before the application of FMEA and 98 patients were set as the experimental group after the application of FMEA.The incidence of unplanned extubation was compared between two groups.Results There was statistically significant difference in unplanned extubation between two groups.Conclusions Application of FMEA can reduce the rate of unplanned extubation of PICC.