Evaluation of right ventricular global and regional volume and systolic function in patients with atrial septal defect using real-time three-dimensional echocardiography
10.3760/cma.j.issn.1004-4477.2013.01.003
- VernacularTitle:实时三维超声心动图评价房间隔缺损患者右心室整体和节段容积及收缩功能
- Author:
Dehong KONG
;
Xianhong SHU
;
Cuizhen PAN
;
Lili DONG
;
Leilei CHENG
;
Daxin ZHOU
- Publication Type:Journal Article
- Keywords:
Echocardiography,three-dimensional;
Ventricular function,right;
Heart septal defect,atrial
- From:
Chinese Journal of Ultrasonography
2013;(1):6-11
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate right ventricular (RV) global and regional volume and systolic function in patients with secondum atrial septal defect (ASD) using real-time three-dimensional echocardiography (RT3DE),and to explore the relationship between parameters derived from RT3DE and parameters measured by conventional echocardiography.Methods RT3DE images were acquired from 22 patients with secundum ASD and 22 normal controls for evaluation and analysis to obtain RV global and regional end-diastolic volume (EDV),end systolic volume (ESV),systolic volume (SV) and ejection fraction (EF) in three compartments (inflow,body and outflow).RV dyssynehrony parameters were calculated as the standard deviation (SD) and maximum difference (dif) of time to minimum systolic volume (Tmsv) and Tmsv corrected by heart rate (Tmsv%) in three RV compartments.Conventional echocardiographic parameters including pulmonary artery systolic pressure (PASP),pulmonary vascular resistance (PVRe) and maximum diameter of ASD (ASD-D) were calculated and recorded.Results RV global and regional EDV,ESV and SV were larger (all P <0.001) and EF was lower (all P <0.05) in the ASD group than in the controls.RV regional volume and systolic function were changed to various degrees in different compartment in the patients group.There were no significant differences in Tmsv,Tmsv% and RV dyssynchrony parameters between the two groups.In patients with ASD,RV global and regional EDV,ESV and SV in the inflow compartment were positively correlated with ASD-D and PASP (r =0.463-0.704,all P < 0.05) ; RV global EF was negatively correlated with PVRe (r =-0.477,P < 0.05).Conclusions In patients with ASD,RV global and regional volume was enlarged and systolic function was impaired with distinct characteristics; RV global volume and regional volume in the inflow compartment were positively correlated with RV pre-load while RV global EF was negatively correlated with RV afterload.