Comparison of accuracy of jugular venous oxygen saturation, somatosensory evoked potentials and motor evoked potentials in estimation of occurrence of intraoperative cerebral ischemia in patients undergoing clipping of intracranial aneurysm
10.3760/cma.j.issn.0254-1416.2012.09.023
- VernacularTitle:颈静脉球血氧饱和度、体感诱发电位和运动诱发电位评估颅内动脉瘤夹闭术患者脑缺血发生准确性的比较
- Author:
Jing HUI
;
Weihua CUI
;
Li LIU
;
Mingran WANG
;
Hui QIAO
;
Dong ZHANG
;
Shuo WANG
;
Ruquan HAN
- Publication Type:Journal Article
- Keywords:
Glomus jugulare;
Oximetry;
Evoked potentials,somatosensory;
Evoked potentials,motor;
Monitoring,intraoperative;
Brain ischemia
- From:
Chinese Journal of Anesthesiology
2012;(9):1111-1114
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the accuracy of jugular venous oxygen saturation (SjvO2),somatosensory evoked potentials (SSEPs) and motor evoked potentials (MEPs) in estimation of the occurrence of intraoperative cerebral ischemia in patients undergoing clipping of intracranial aneurysm.Methods Forty-three ASA Ⅰ or Ⅱ patients of both sexes,aged 18-64 yr,with a body mass index of 20-25 kg/m2,undergoing clipping of intracranial aneurysm,were studied.Anesthesia was induced with sufentanil,rocuronium and propofol.The patients were tracheal intubated and mechanically ventilated.Anesthesia was maintained with remifentanil and propofol.Blood samples were taken from the jugular bulb for detection of SjvO2 before aneurysm clipping or temporary occlusion of parent artery and at 1,3,10,20 and 30 min after clipping aneurysm or temporary occlusion of parent artery.The amplitude and latency of SSEPs and MEPs were recorded simultaneously.The occurrence of cerebral ischemia estimated by SjvO2,SSEPs and MEPs was recorded.The condition of nerve defect was recorded within 3 days after operation and the gold standard of cerebral ischemia was defined as the occurrence of nerve defect.Results Among 43 patients,14 cases were diagnosed as having brain ischemia.The sensitivity and specificity of SjvO2 in estimation of the occurrence of intraoperative brain ischemia were 71% and 93%,respectively (P < 0.01).The sensitivity and specificity of SSEPs in estimation of the occurrence of intraoperative brain ischemia were 71% and 62%,respectively (P < 0.05).When the diagnostic criterion of cerebral ischemia was defincd as a decrease in the amplitude of MEPs or prolongation of the latency MEPs,the sensitivity and specificity of MEPs in estimation of the occurrence of intraoperative brain ischemia were 79 % and 52 %,respectively (P > 0.05).When the diagnostic criterion of cerebral ischemia was defined as a loss of the amplitude of MEPs,the sensitivity and specificity of MEPs in estimation of the occurrence of intraoperative brain ischemia were 57% and 93%,respectively (P <0.05).Conclusion The sensitivity of SjvO2 and SSEPs in estimation of the occurrence of intraoperative brain ischemia is higher,however,the specificity of SjvO2 and MEPs is higher,indicating that SjvO2 is a reliable criteria for estimation of the occurrence of intraoperative brain ischemia in patients undergoing clipping of intracranial aneurysm.