The effect of minimally invasive lock pressurized titanium plate plus bone graft on distal tibial fracture
10.3760/cma.j.issn.1008-6706.2012.23.018
- VernacularTitle:微创锁内加压钛板固定加植骨术治疗胫骨远端骨折
- Author:
Juntao CHEN
- Publication Type:Journal Article
- Keywords:
Tibial fractures;
Surgical procedures,minimally invasive;
Fracture fixation;
Invasive lock pressurized titanium plate
- From:
Chinese Journal of Primary Medicine and Pharmacy
2012;(23):3554-3555
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the effectiveness of minimally invasive lock pressurized titanium plate plus bone graft on distal tibial fracture.Methods 63 patients with distal tibial fracture were enrolled.They were operated through minimally invasive lock pressurized titanium plate plus bone graft.The Iowa was compared after follow-up.Results The fractures were all healed with three pin tract infection and nonunion.Iowa was(67.2±24.5)before operation and(93.7±29.1)after twelve months(P<0.01).The excellent cases were 30 paeitnts,the good 28 cases,the suit 5 cases and the poor 0 cases.The excellent rate was 92.1%.Conclusion Minimally invasive lock pressurized titanium plate plus bone graft was an effe(ct)ive operation for distal tibial fracture.