New minimally invasive technique of peratrial device closure of ventricular septal defect through a right parasternal approach
10.3760/cma.j.issn.1001-4497.2012.12.003
- VernacularTitle:经右胸—右心房途径微创室间隔缺损封堵术
- Author:
Hongxin LI
;
Fei LIANG
;
Wenbin GUO
;
Nan ZHANG
;
Cunbao GUO
;
Chengwei ZOU
;
Guidao YUAN
- Publication Type:Journal Article
- Keywords:
Ventricular septal defect;
Surgical pocedures,minimally invasive;
Device
- From:
Chinese Journal of Thoracic and Cardiovascular Surgery
2012;(12):712-715
- CountryChina
- Language:Chinese
-
Abstract:
Objective The aim of this study was to evaluate the feasibility,safety and efficacy of peratrial device closure of ventricular septal defect (VSD) through a right parasternal approach.Methods Between May 2011 and July 2012,47 patients (peratrial group),aged 7 months to 37 years,underwent peratrial device closure of VSD through a right parasternal approach.According to the same inclusion criteria,47 patients who underwent perventricular device closure of VSD were randomly chosen as the control group (perventricular group).In the peratrial group,a 1.5 to 2.0 cm parasternal incision was made in the right fourth or third intercostal space.The pericardium was incised and cradled.Two parallel pursestring sutures were placed at the right atrium near the atrioventricular groove.After puncture,a specially designed hollow probe was inserted into the right atrium.The probe was passed through the tricuspid valve into the right ventricle.Under transesophageal echocardiographic guidance,the tip of the probe was adjusted to point to or cross the defect.A flexible guidewire was rapidly inserted into the left ventricle through the channel of the probe to establish a delivery pathway,and the delivery sheath was introduced through the defect over the wire.Then the device was deployed to close the defect.Results Successful implantation of the device was achieved in both groups of patients (100%).In the peratrial group,the entrance and the exit diameter of the VSD were (7.4 ±4.1) mm (range,2.0 to 20.0 mm) and (3.4 ± 1.2)mm (range,2.0 to 7.0 mm),respectively.The mean device size was (6.3 ± 1.5)mm (range,4.0 to 12.0 mm).The mean intracardiac manipulation time is longer in the peratrial group [(15 ± 13) min] than in the perventricular group[(8 ± 5)min],P < 0.01.But the procedure time is shorter in the peratrial group[(56 ± 24) min] than in the perventricular group [(72 ± 16) min],P < 0.01.During the follow-up period of 1 to 12 months,no device-related complications were found.Conclusion The peratrial device closure of VSD is feasible,safe,and efficacious.It has the advantages of less invasiveness,better cosmetic results,and a shorter procedure time.