Hybrid procedure for infants with ventricular septal defect and coarctation of aorta: a review of 20 cases
10.3760/cma.j.issn.1001-4497.2012.08.003
- VernacularTitle:“杂交”手术治疗20例小婴儿主动脉缩窄合并室间隔缺损
- Author:
Gang CHEN
;
Bing JIA
;
Fang LIU
;
Lin WU
;
Ming YE
;
Mengyü CHENG
- Publication Type:Journal Article
- Keywords:
Aorta coarctation;
Ventricular septal defects;
Balloon dilation;
Hybrid procedure
- From:
Chinese Journal of Thoracic and Cardiovascular Surgery
2012;28(8):456-458
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the early clinical efficaoy of hybrid procedure for infants less than six months old with ventricular septal defect and coarctation of aorta.Methods From January 2010 to July 2011,20 patients with ventricular septal defect and coarctation of aorta received hybrid procedure in our center.The body weight was (4.5 ± 1.6) kg ( ranged from 1.9 kg to 6.5 kg) and the age was ( 56 ± 45 ) days ( ranged from 18 days to 6 months).The pressure gradient of the coarctation of the aorta ranged from 30 mm Hg to 56 mm Hg,5 patients of them were diagnosed as hypoplasty of aortic arch.The size of the ventricular septal defect ranged from 8 mm to 16 mm.Results The mortality was zero in all the 20 cases during the surgery,and the mobidity was 20% (4/20).The complications were pneumonia in 2 cases,infective endocarditis in 1 case and pneumothorax in 1 case.The diameter of coarctation of the aorta ranged from 1.5 mm to 3.4 mm,and the size of the balloon ranged from 4 mm to 12 mm.The pressure gradient of the coarctation of the aorta decreased to 0 to 27 mm Hg.The bypass time ranged from 40 minutes to 87 minutes,and the crossclamp time of the aorta ranged from 20 minutes to 41minutes.The atrial septal defects were repaired and the patent ductuses were ligated during the surgery without leaving the sternum open.The total operation time was (4.0 ± 0.7 ) hours ( ranging from 3.0 hours to 5.2 hours).The mean ventilation time was (2.2 ± 1.4) days and mean ICU stay time was (5 ± 3 ) days.All the patients were followed up for ( 10.0 ± 3.6) months without aneurysm in arch and obstruction in airway.The residual obstructive pressurc gradicnt in the aortic arch ranged from 12 mm Hg to 35 mm Hg and 2 patients received reintervention.One patient received re-balloon dilation and the other received surgery.The cardiac function reached NYHA Ⅰ - Ⅱ in all eases.Conclusion The early outcome of the hybrid procedure (balloon dilation of the coartation of the aorta and surgical repair of ventricular septal defect) for infants with ventricular septal defect and coarctation of aorta was satisfying,which could avoid from circulatory arrest.It is a relatively safe procedure which could be the optional method for one-stage surgical repair.