Abstract:
ObjectiveTo investigate the clinical value of right lateral position with real-time monitor for capsule endoscopy.MethodsA total of 80 patients were randomly divided into two groups.The observation group assumed the right lateral position,while the control group was in upright,standing or sitting position.The capsule endoscope was monitored real time.The patients were allowed to move after the capsule endoscope passed pylorus.Gastric transit time,small bowel transit time,small bowel examination completion rate and positive detection rate were compared between the two groups.ResultsThe mean gastric transit time of the observation group was (31.7 ± 29.8)min,which was significantly shorter than that in the control group (62.6 ± 55.9) min ( U =559.000,P =0.020).The mean transit time of small bowel was (221.3 ±78.8) min in the observation group,which was not significantly different from that of the control group ( t =0.511,P =0.611 ).The examination completion rate of whole small bowel was 95.0% (38/40)in the observation group,which was significantly higher than that of the control group (x2 =5.165,P =0.023).The positive detection rates were 75.0% (30/40) and 65.0% (26/40),respectively,which were not significantly different (x2 =0.952,P =0.329).ConclusionThe right lateral position with real-time monitor during capsule endoscopy is of better clinical value.