The influence of pacing site to left ventricular myocardial contraction patterns and function
10.3760/cma.j.issn.1004-4477.2012.07.001
- VernacularTitle:起搏位点对左心室收缩模式及功能的影响
- Author:
Jing YAO
;
Di XU
;
Chun CHEN
;
Jing XU
;
Changqing MIAO
;
Yonghong YONG
;
Ling JI
;
Yan ZHUANG
;
Minglong CHEN
;
Kejiang CAO
- Publication Type:Journal Article
- Keywords:
Echocardiography;
Cardiac pacing,artificial;
Ventricular function,left;
Speckle tracking imaging
- From:
Chinese Journal of Ultrasonography
2012;(7):553-557
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate left ventricular(LV)myocardial contraction patterns and function when pacing in different right ventricular(RV)sites and discuss echocardiogarphic method to evaluate physiologcal pacing mode.Methods This study included 26 patients with paroxysmal supraventricular tachycardia without organic heart disease.Four pacing modes including right atrium pacing(AAI),RV apex pacing(VVI-RVA),RV septal pacing(VVI-IVS)and RV outflow tract pacing(VVI-RVOT)were performed on the patients in a random order after succussful radiofrequency ablation.The parameters measured in each pacing mode included(1)LV systolic function parameters:LV twist angle(Twist),aortic systolic velocity-time integral(VTIAo)and LV global strain(Gε);(2)LV contracting pattern:segmental peak systolic strain(Sε),the time to peak value(TPε),and the distribution of segmental Sε,TPε in each layer or wall.The relationship between Sε,TPε of each wall was analyzed.[Results]Pacing from RV sites showed lower Twist,VTIAO and Gε than AAI mode.Gε demonstrated significant difference in three RV sites pacing mode(VVI-RVOT>VVI-IVS>VVI-RVA,P<0.05).Compared with the AAI mode,the distribution of segmental Sε,TPε in the each layer or wall alerted significantly in three RV sites pacing mode,especially in VV1-RVA.The distribution pattern was similar in VVI-RVOT and VVI-IVS.Furthermore,the wall Sε collated negtively with wall TPε(r =-0.51,P<0.001).[Conclusions]Compared with AAI mode,RV pacing,especially the VVI-RVA induced the alternation of LV contraction patterns and reduction of systolic function.Longitudinal strain parameters can be used to assess the myocardial contraction patterns and function in different pacing mode.