Study on the weaning method of mechanical ventilation in the treatment of 51 patients with acute severe respiratory failure caused by organophosphate poisoning
10.3760/cma.j.issn.1008-6706.2012.10.006
- VernacularTitle:机械通气治疗急性重度有机磷中毒致呼吸衰竭患者撤机方法探讨
- Author:
Zhihong ZHENG
- Publication Type:Journal Article
- Keywords:
Organophosphate poisoning;
Mechanical ventilation;
Weaning
- From:
Chinese Journal of Primary Medicine and Pharmacy
2012;19(10):1450-1452
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo explore the weaning method of mechanical ventilation in the treatment of acute severe respiratory failure caused by organophosphate poisoning.MethodsThe clinical features and weaning situation of 51 patients with acute severe respiratory failure caused by organophosphate poisoning by the treatment of mechanical ventilation were retrospectively analyzed.ResultsIn 51 cases,45 cases were cured,the survival rate was 88.2% and 6 cases died,the fatality rate 11.8%.Conclusion Early ventilator to rescue and choose opportunity for weaning could directly impact on the qualitv of life of patients,and improve outcomes,and reduce mortality.