Abstract:
Objective To discuss quality control in clinical laboratory of bacteriology test.Methods From 2009 to 2011,clinical isolates of bacterial samples were retrospectively analyzed.Results The eligible rate of bacterial sample was 92.7%.Abscess and trauma sample (97.8%),blood sample (96.9%) and urinary or vaginal discharges sample(91.9% ) were in the top three after the test.The unqualified rates of bacterial sample were 7.3% (279/3800).Conclusion Acquisition and processing of bacterial sample tightly was the key to quality assurance of bacterial sample in clinical laboratory of bacteriology test.