Enamel dose calculation by electron paramagnetic resonance spectral simulation technique
10.3760/cma.j.issn.0254-5098.2011.06.024
- VernacularTitle:用电子顺磁共振波谱拟合方法估算牙釉质辐射剂量
- Author:
Guofu DONG
;
Jianbo CONG
;
Linchao GUO
;
Jing NING
;
Hong XIAN
;
Changzhen WANG
;
Ke WU
- Publication Type:Journal Article
- Keywords:
Electron paramagnetic resonance;
Spectral simulation;
Enamel;
Dose estimation
- From:
Chinese Journal of Radiological Medicine and Protection
2011;31(6):709-712
- CountryChina
- Language:Chinese
-
Abstract:
Objective To optimize the enamel electron paramagnetic resonance (EPR) spectral processing by using the EPR spectral simulation method to improve the accuracy of enamel EPR dosimetry and reduce artificial error.Methods The multi-component superimposed EPR powder spectral simulation software was developed to simulate EPR spectrum models of the background signal(BS) and the radiation- induced signal (RS) of irradiated enamel respectively.RS was extracted from the multi-component superimposed spectrum of irradiated enamel and its amplitude was calculated.The dose-response curve was then established for calculating the doses of a group of enamel samples.The result of estimated dose was compared with that calculated by traditional method.Results BS was simulated as a powder spectrum of gaussian line shape with the following spectrum parameters:g =2.00 35 and Hpp =0.65 - 1.1 mT,RS signal was also simulated as a powder spectrum but with axi-symmetric spectrum characteristics.The spectrum parameters of RS were:g(1) =2.0018,g (11) =1.996 5,Hpp =0.335 - 0.4 mT.The amplitude of RS had a linear response to radiation dose with the regression equation as y =240.74x + 76 724 ( R2 =0.9947 ).The expectation of relative error of dose estimation was 0.13.Conclusions EPR simulation method has improved somehow the accuracy and reliability of enamel EPR dose estimation.