Effects of ventilator circuit change frequency on ventilator-associated pneumonia: Meta-analysis
10.3760/cma.j.issn.1671-0282.2012.06.007
- VernacularTitle:呼吸机管路更换对呼吸机相关肺炎影响的荟萃分析
- Author:
Aiping WU
;
Chun PAN
;
Fengmei GUO
;
Haibo QIU
- Publication Type:Journal Article
- Keywords:
Mechanical ventilation;
Ventilator circuit change;
RCT;
Ventilator-associated pneumonia;
Incidence;
Meta-analysis
- From:
Chinese Journal of Emergency Medicine
2012;21(6):587-591
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo evaluate the effects of ventilator circuit change frequency on ventilatorassociated pneumonia (VAP).MethodsMeta-analysis of effects of ventilator circuit change frequency on VAP was conducted with study-level data from 1995 to 2010 in Pubmed,Embase,Web of Science databases.ResultsNine articles were included (sample size:20 326 mechanically ventilated patients).Analysis of six articles showed that the incidence of VAP in ventilator circuit change every 2 or 3 days was 4.05%,while 3.65% in ventilator circuit change every 7 days.Compared with change ventilator circuit every 2 or 3 days,the risk ratio (RR) of VAP in weekly changes was 0.77 [0.54,1.09] ( P =0.14 ).Analysis three articles showed that compared to ventilator circuit change every 7 days with 15.89% incidence of VAP,the incidence of VAP in circuit change more than 14 days was 14.9%,and RR was 0.98 [0.69,1.39](P =0.91 ).ConclusionsRegular ventilator circuit change frequency in various intervals can't difference in the incidence of VAP in mechanical ventilation patients.