Study the feasibility in the application of RapidArc associated with active breath coordinator for radiotherapy of hepatocelluar carcinoma
10.3760/cma.j.issn.1004-4221.2012.01.018
- VernacularTitle:ABC辅助下RapidArc放疗原发性肝癌的可行性研究
- Author:
Guanzhong GONG
;
Yong YIN
;
Tonghai LIU
;
Jinlong SONG
;
Jie LU
;
Jinhu CHEN
;
Changsheng MA
;
Dongping SHANG
;
Ruozheng WANG
- Publication Type:Journal Article
- Keywords:
Radiotherapy,RapidArc;
Radiotherapy,intensity-modulated;
Radiotherapy,three-dimensional conformal;
Active breath coordinator;
Hepatocellular carcinoma
- From:
Chinese Journal of Radiation Oncology
2012;21(1):63-67
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo study the feasibility of RapidArc (RA) associated with active breath coordinator (ABC)for hepatocelluar carcinoma (HCC)radiotherapy comparing of three-dimensional conformal radiotherapy (3DCRT),intensity modulated radiotherapy (IMRT),RA treatment plans in different breath status.Methods12 HCC cases were selected.Three series CT scanning were completed in Free Breathing (FB),End Inspiration Hold (EIH) and End Expiration Hold (EEH) associated with ABC device.3DCRT,IMRT and RA (three 135° arcs) treatment plans were respectively designed on planning target volume (PTV) in different breath status.The dosimetric differences among 3 DCRT,IMRT and RA,among RA plans under different breath status were compared.ResultsThe PTV in FB was larger than in EEHand EIH (160.8 cm3,89.5 cm3,83.1 cm3,F=6.63,P=0.004). The conformity index and homogeneity index of RA plans were better than IMRT and 3DCRT ( 0.92,0.90,0.77,F =72.55,P =0.000 ;0.90,0.89,0.84,F =125.49,P =0.000 ) ;the V20,V30,V40 of normal liver in 3DCRT were higher than IMRT and RA (24%,20%,19%,F=3.56,P =0.032;13%,10%,10%,F=5.74,P =0.004;8%,5%,6%,F =3.72,P =0.027).The normal liver mean dose,V10,V20,V30,V40 of RA plans in FB were higher than in EEH and EIH ( 13.46 Gy,10.25 Gy,9.48 Gy,F =3.627,P =0.038 ;46%,35%,32%,F =2.96,P=0.066;24%,16%,16%,F=3.69,P=0.036;13%,8%,8%,F=4.28,P=0.022;8%,5%,5%,F =2.39,P =0.108 ).The duodenum D5 cm3 of RA in EEH was lower than in FB and EIH (8.78 Gy,19.35 Gy and 11.67 Gy,F =1.56,P =0.224 ).The mean monitor units for 3 DCRT,IMRT,RA was 254.06 MU,626.33 MU and 550.28 MU ( F =147.35,P =0.000 ),while the mean treatment time was 135 s,540 s and 130 s respectively (F =62.83,P =0.000).ConclusionsThe RapidArc applying three 135°arcs with ABC in HCC radiotherapy can achieve better PTV coverage than IMRT with fewer monitor units,shorter treatment time and sparing more normal liver.