Analysis of surgical treatment of 205 cases of spinal fracture
- VernacularTitle:脊柱骨折205例手术治疗分析
- Author:
Chunhua TAN
;
Zhenhe GUO
;
Daohai LU
;
Zhe WEN
;
Yiquan CHENG
;
Kun HE
- Publication Type:Journal Article
- Keywords:
Spinal fracture;
Vertebral pedicle screw;
Internal fixation;
Reduction position
- From:
Journal of Chinese Physician
2011;(z1):32-35
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the surgical treatment of spinal injury, and provide insights on key points and related issues for operations. Methods Two hundred and five cases of spinal fracture were treated through posterior surgical treatment. Under C-arm X-ray monitoring, surgeries had been operated on pedicle screws insertion, vertebral canal decompression, over-extending reduction position, and placed the connecting rod, knocked in the bone graft and finally transplanted the paraspinal bone. Results After operations , the height and morphology of vertebral bodies and spinal physiological curvature were basically recovered analyzed by X ray examination. The follow-up results (in the average of 14 to 36 months) indicated that there were 4 cases of delayed infection, 7 cases of loosen screw, 6 cases of broken screw (14 screws)and 1 case of broken stick, with no secondary nerve injury or other syndromes. Conclusion The vertebral pedicle screw internal fixation manipulated easily, which could sufficiently enlarge vertebral canal in order to decompression. In addition, during the operation, together with over-extending reduction position is beneficial to regain the height of fractured vertebral bodies.