Clinical study on security of mechanical filter in patients with mechanical ventilation
10.3760/cma.j.issn.1008-6706.2011.12.021
- VernacularTitle:机械式过滤器应用于机械通气患者的安全性研究
- Author:
Yunqi LU
;
Meise LIN
;
Yinquan MA
- Publication Type:Journal Article
- Keywords:
Mechanical filter;
Mechanical ventilation;
Security
- From:
Chinese Journal of Primary Medicine and Pharmacy
2011;18(12):1627-1628
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the security of mechanical filter in mechanical ventilation for ICU patients.Methods 60 patients treated with mechanical ventilation and conventional airway humidification were selected and randomly divided into treatment group(mechanical filter treatment) and control group(non filter treatment) ,30 cases in each group.The changes of respiratory function(airway plateau pressure,endogenous PEEP and arterial carbon dioxide partial pressure of 2h,12h,24h at the first day of mechanical ventilation) ,and the incidence and mortality of ventilator-associated pneumonia were observed.Results The study showed airway resistance and the work of breathing in treatment group did not increase,and no hypercapnia due to congestion occurred.The incidence of ventilator-associated pneumonia in treatment group was significantly lower than that of the control group (26.7% vs 56.7% ,x2 = 5.554,P = 0.018).Conclusion Mechanical filer applied in patients with mechanical ventilation was safe and could decrease the incidence of ventilator-associated pneumonia.