Determination of Fluorouracil in Human Serum With HPLC
- VernacularTitle:高效液相色谱法测定人血清中5-氟尿嘧啶的浓度
- Author:
Shuibao YAO
;
Shuixin YANG
- Publication Type:Journal Article
- From:
China Pharmacy
2001;12(4):227-228
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE: To determine the content of 5-Fu in human serum.METHODS: Serum protein was precipitated with trichloroacetic acid .HPLC was used for determination of 5-Fu .The column was Shimpack CLC C18(150 × 6mm, 5μm)with YWG for protection.The mobile phase was 0.25% KH2PO4-acetonitrile(98: 2, pH7.0) .The flow rate was 1ml/min.The detection wavelength was 265nm.Two standard curves were made in the concentrations of 0.195~6.250μg/ ml and 6.25~200.00μg/ml, respectively.RESULTS: The calibration curves revealed linearity in the range of 0.195~200μg/ml.The with-in-day recoveries and RSDs of 5-Fu at 0.8, 4, 20 and 100μg/ ml concentration points were 104. 88%, 1.95%; 104.58%,1.38%; 101.40%, 0.39%and 99.14%, 0.37%, and the between-day recoveries and RSDs of 5-Fu were 105.12%, 2.02%;106.30 %, 0.78 %; 100.60 %, 0.65 % and 99.38 %, 0.92 % respectively. CONCLUSION: This method is rapid, accurate and suitable for pharmacokinetical study and conventional monitoring of 5-Fu.