Neonatal ventilator associated pneumonia
- VernacularTitle:新生儿机械通气相关性肺炎(附22例报告)
- Author:
Zhiling ZU
;
Fei GAO
;
Bin YANG
;
Hui LU
;
Xindong XUE
- Publication Type:Journal Article
- From:
Chinese Pediatric Emergency Medicine
2001;8(1):18-19
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate clinical features of neonatal ventilator associated pneumonia.Methods Retrospective analysis of clinical features was performed in twenty-two newborns with ventilator associated pneumonia.Results Ventilator associated pneumonia were found in 22 ou t of 36 neonates with mechanical ventilation.Conclusion The incidence of VAP is significantly increased if the time of mechanical ventilation in longer than 96 hours.