Evaluative merit of brain blood perfusion image of single photon emission computed tomography on local brain blood distribution in neonatal hypoxic ischemic encephalopathy
- VernacularTitle:单光子发射型计算机体层摄影脑血流灌注显像评估缺氧缺血性脑病新生儿局部脑血流量的分布
- Author:
Yajie LIU
;
Tieli ZHANG
;
Leijia ZHANG
;
Shukun YANG
;
Guilan MA
- Publication Type:Journal Article
- From:
Chinese Journal of Tissue Engineering Research
2005;9(15):248-249
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND: Neonatal hypoxic ischemic encephalopahty(NHIE) is a common neonatal disease, which could cause cerebral palsy, inferior intelligence and convulsion. At present, usual examinations for this disease are CT.MRI and single photon emission computed tomography(SPECT), etc.OBJECTIVE: To investigate the character of SPECT image of NHIE, and compared with CT and MRI as well to provide a theoretical gist for function surveillance and early intervention of NHIE.DESIGN: An observatory comparative study based on NHIE patients and normal neouates as control.SETTING: Department of nuclear medicine in a medical university hospital.PARTICIPANTS: Thirty neonates hospitalized in the Department of Pediatrics, Affiliated Hospital of Jining Medical College between September 1998 and October 2000 were selected as observation group with 23 males and 7 females. Another 10 normal neonates including 7 males and 3 females were randomly selected from same period into control group.METHODS: SPECT brain blood perfusion was conducted in the subjects of two groups and the results were compared with that of CT and MRI.MAIN OUTCOME MEASURES: ① comparison of SPECT brain blood image features between NHIE and normal neonates; ② comparison of SPECT images and CT, MRI results. RESULTS: In 22 NHIE cases who received SPECT, CT and MRI simultaneously, mild group had 7 cases, and positive cases of SPECT, CT or MRI was 7, 3 or 5; moderate group had 10 cases, and positive cases of three methods was 10, 8 or 9; severe group had 5 cases, the all of them were positive in all three examinations. The total positive detectable rate of SPECT, CT or MRI was 100, 72.73% or 86. 36%. There was no significant difference of sensitivity between SPECT and MRI in mild group, while there was significant difference between SPECT and CT(x2 = 3.95, P < 0.05);there was no significant difference among three methods in either moderate group or severe group(x2 =0. 83, P > 0.05).CONCLUSION: SPECT brain blood perfusion image is a quite sensitive method for the surveillance of NHIE, which can provide imageological reference for the evaluation of its prognosis and early intervention.