Biological membrane for repair of different sizes of bone defects surrounding BLB implants
- VernacularTitle:生物膜对不同范围BLB种植体周骨缺损修复的影像学观察
- Author:
Weiyan MENG
;
Yanmin ZHOU
;
Shunli CHU
;
Liming YANG
;
Qing CAI
- Publication Type:Journal Article
- From:
Chinese Journal of Tissue Engineering Research
2008;12(49):9771-9774
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND:There is often space between implant and bone during immediate implantation.Whether biological membrane is needed to guide bone regeneration remains poorly understood.OBJECTIVE:To createdifferent sizes of space between femurand implantsindogs and to observe the effects of biological membrane on bone regeneration capacity of bone defects surrounding implants.DESIGN,TIME AND SETTING:A self-control animal experiment was performed at the Laboratory Animal Center,Norman Bethune College of Medicine,Jilin University and School of Stomatology,Jilin University between March and December 2005.MATERIALS:BLB hydroxyapatite-coated implant was provided by Beijing Leiden Biomaterial Co.,Ltd.,China;BME-10X collagen membrane was purchased from Fujian Better Biotechnology Co..Ltd.,China.METHODS:BLB implants were installed in the bilateral proximal femoral bone to create standard gradient bone defects with horizontal width 3 mm.vertical depth 5 mm,and horizontal lengths of 0,1,2,3,and 4 mm Bone defects on the left femur were sutured directly and those on the right femur were covered with biological membrane prior to suture.All animals were sacrificed at 3 months after surgery.Specimens containing implants were harvested to prepare tissue blocks for radiological observation.MAIN OUTCOME MEASURES:The quantity,color,and texture of newly formed bone surrounding implants were observed from the surface and profile levels.The implant-bone integration and new bone formation were also examined by soft X-ray photography.RESULTS:Grossobservation results revealed that when the horizontal length of bone defect was 3 mm or less,there was no significant differenee in bone density between the newly formed bone and the host bone no matter whether biological membrane existed or not;when the horizontal length of bone defect was 4 mm the bone density was better when biological membranes were used than not.Soft X-ray photography results revealed that when the horizontal length ofbone defect was 3 mm or less.no significant difference in bone density and bone trabecular morphology and orientating was found between newly formed bone and host bone no matter whether biological membrane was used or not;in the 4-mm-length bone defect areas.implants contacted with newly formed bone directly,but the calcified degree ofnewly formed bone was poor,bone trabecula was thin,and bone trabecular course was irregular,nevertheless,the calcified degree of newly formed bone was better under the condition of being with biological membrane than without biological membrane.CONCLUSION:Biological membrane exhibits strong capacity to promote the regeneration and repair of bone defect tissue with a horizontal length of 3 mm or less,and plays an important role in repatr of large sizes of bone detect